STARTUP=SUT0, FWUP=OFF, USEQ=NUM_ORDER, FREERUN=OFF, SLEEP=NORMAL, TRGSEL=AFEC_TRIG0, TRGEN=DIS
AFEC Mode Register
TRGEN | Trigger Enable 0 (DIS): Hardware triggers are disabled. Starting a conversion is only possible by software. 1 (EN): Hardware trigger selected by TRGSEL field is enabled. |
TRGSEL | Trigger Selection 0 (AFEC_TRIG0): AFE0_ADTRG for AFEC0 / AFE1_ADTRG for AFEC1 1 (AFEC_TRIG1): TIOA Output of the Timer Counter Channel 0 for AFEC0/TIOA Output of the Timer Counter Channel 3 for AFEC1 2 (AFEC_TRIG2): TIOA Output of the Timer Counter Channel 1 for AFEC0/TIOA Output of the Timer Counter Channel 4 for AFEC1 3 (AFEC_TRIG3): TIOA Output of the Timer Counter Channel 2 for AFEC0/TIOA Output of the Timer Counter Channel 5 for AFEC1 4 (AFEC_TRIG4): PWM0 event line 0 for AFEC0 / PWM1 event line 0 for AFEC1 5 (AFEC_TRIG5): PWM0 event line 1 for AFEC0 / PWM1 event line 1 for AFEC1 6 (AFEC_TRIG6): Analog Comparator |
SLEEP | Sleep Mode 0 (NORMAL): Normal mode: The AFE and reference voltage circuitry are kept ON between conversions. 1 (SLEEP): Sleep mode: The AFE and reference voltage circuitry are OFF between conversions. |
FWUP | Fast Wake-up 0 (OFF): Normal Sleep mode: The sleep mode is defined by the SLEEP bit. 1 (ON): Fast wake-up Sleep mode: The voltage reference is ON between conversions and AFE is OFF. |
FREERUN | Free Run Mode 0 (OFF): Normal mode 1 (ON): Free Run mode: Never wait for any trigger. |
PRESCAL | Prescaler Rate Selection |
STARTUP | Start-up Time 0 (SUT0): 0 periods of AFE clock 1 (SUT8): 8 periods of AFE clock 2 (SUT16): 16 periods of AFE clock 3 (SUT24): 24 periods of AFE clock 4 (SUT64): 64 periods of AFE clock 5 (SUT80): 80 periods of AFE clock 6 (SUT96): 96 periods of AFE clock 7 (SUT112): 112 periods of AFE clock 8 (SUT512): 512 periods of AFE clock 9 (SUT576): 576 periods of AFE clock 10 (SUT640): 640 periods of AFE clock 11 (SUT704): 704 periods of AFE clock 12 (SUT768): 768 periods of AFE clock 13 (SUT832): 832 periods of AFE clock 14 (SUT896): 896 periods of AFE clock 15 (SUT960): 960 periods of AFE clock |
ONE | One |
TRACKTIM | Tracking Time |
TRANSFER | Transfer Period |
USEQ | User Sequence Enable 0 (NUM_ORDER): Normal mode: The controller converts channels in a simple numeric order. 1 (REG_ORDER): User Sequence mode: The sequence respects what is defined in AFEC_SEQ1R and AFEC_SEQ1R. |